At present, there are CL-1-4S and CL-1-8 two products in this series.
CL-1-4S is a four-paths product, which is the first domestic product applied to the custody measurement of high-pressure natural gas. The product technology is at the international advanced level, and has been widely used in the PipeChina, and other natural gas pipeline projects. CL-1-8 is the latest eight-paths product, and its technical performance is in the international leading level, which can provide users with higher accuracy guarantee and reliability redundancy. lt has a larger scale ratio of 80:1 to 100:1 with more sound paths, so that in the condition of one individual sound path failed, it could continue to use other normal sound paths for effective measurement and does not affect the normal use of users; The 8 sound paths in the paralleled reflection pair layout can effectively solve the influence of the flow field distortion in the pipeline, such as turbulence flow, swirling flow, pulsating flow and other uncertain flow fields on the gas ultrasonic measurement accuracy, besides it has lower requirements on the length of front and rear straight pipe sections with convenient installation and application in compact sites. " />

168gbt贵宾会(中国)有限公司官网

/uploads/images/20240410/9024ca224d7b72e6f885f7b4b31daf0e.png
/uploads/images/20240410/475f7c33b89cb53f5ebd33c1f4d1c8f5.png
/uploads/images/20240410/5b4f0fd0828a8111fb2a7d56ab8e4381.png
/uploads/images/20240410/947db039484f893daf07e7eb42c209e5.png
/uploads/images/20240410/35a4f47328f5a30d23c550d1a6a65347.png

CL-1 Series Ultrasonic Gas Flow Meter

Product Introduction
CL-1 series product measuring bores covering from DN50 ~ DN700, measuring accuracy reaches 0.5 above, it is suitable for accurate and reliable custody transfer of natural gas long distance pipeline, also it is suitable for all kinds of medium and low pressure situations under the condition of natural gas, city gas, large industrial users with high precision flow metering and monitoring.
At present, there are CL-1-4S and CL-1-8 two products in this series.
CL-1-4S is a four-paths product, which is the first domestic product applied to the custody measurement of high-pressure natural gas. The product technology is at the international advanced level, and has been widely used in the PipeChina, and other natural gas pipeline projects. CL-1-8 is the latest eight-paths product, and its technical performance is in the international leading level, which can provide users with higher accuracy guarantee and reliability redundancy. lt has a larger scale ratio of 80:1 to 100:1 with more sound paths, so that in the condition of one individual sound path failed, it could continue to use other normal sound paths for effective measurement and does not affect the normal use of users; The 8 sound paths in the paralleled reflection pair layout can effectively solve the influence of the flow field distortion in the pipeline, such as turbulence flow, swirling flow, pulsating flow and other uncertain flow fields on the gas ultrasonic measurement accuracy, besides it has lower requirements on the length of front and rear straight pipe sections with convenient installation and application in compact sites.
Online consultation

Product Details

  • Technical Parameter
  • Flow Range
  • Installation Indication
  • Technological Advantage
  • Main Technical Parameters

    1672729094440647.png


    Principle of measurement

    Ultrasonic time difference method

    Measuring medium

    Natural gas, air and other special gases

    Number of paths

    Four or eight paths

    path layout

    Four  paths is Paralleled direct; 8 paths is Crossed direct

    Measurement range

    0.1-30m/s(High flow rate customizable)

    Resolution Rate

    0.001m/s

    Speed sampling interval

    ≤0.1s

    Accuracy Class

    0.5 Class

    Repeatability

    For common conditions, Qt~Qmax:≤ 0.1%(Customizable according to customer requirements: Qt~Qmax:≤ 0.05%)

    Transitional flow point

    For common conditions,Qt≤0.1Qmax,(Customizable according to customer requirements: Qt≤0.05Qmax)

    Overload capacity

    ≥120% Qmax( no impact on short duration)

    Measuring Bore

    4 paths: DN50~DN400,8 paths: DN100~DN400 ( larger diameter customizable)

    Nominal pressure

    PN16, PN40, PN63;Class150, Class300, Class600, Class900 Class1500, Class2500



    Measurement Requirements

    1672731262985935.png


    Medium Temperature

    -20~80℃ 、-40~80℃( -40~200℃ customizable )

    Medium Pressure

    0-42.0MPa

    The Environment Temperature

    -30~60℃,-45~60℃( More special ambient temperatures can be customized )



    Material Selection

    1672734374101087.png


    Meter Body

    Cast steel: WCB, LCB; Forged steel :16 MnD,A105, LF2, duplex stainless steel, 304, 316 or 316L stainless steel

    Converter

    Aluminum alloy, stainless steel (customizable)

    Transducer

    All metal (316 ss, titanium alloy)



    Operating Requirements

    1672734566369483.png


    Power Supply

    24V DC

    Power Consumption

    <4W

    Transducer Frequency

    120 kHz 、160kHz、200kHz、250kHz (Selection of appropriate frequencies according to operating conditions)



    Signal Input, Output and Other Functions

    1672734807940918.png


    Electrical Interface

    four NPT 1/2 "(F)

    Analog input

    3 channels temperature and pressure transmitter signals

    Analog output

    2 channels 4-20 mA (1 channel support HART)

    Frequency/pulse output

    2 channels 5V or OC door

    communication interface

    3 channels Rs 485, 1 channel RS485 or HART output(alternative), 1 channel Ethernet

    communication protocol

    Standard MODBUS Communication Protocol

    Digital output

    3 channels DO alarm and other information output

    LCD display

    on site display: instantaneous flow, cumulative flow, real-time temperature, pressure and other information

    data storage time

    Historical data can be maintained for at least 8 years (annual cumulative, monthly cumulative), alarm records can be maintained for at least 10 years

    operation method

    The operating parameters of the flowmeter are set by the software of the upper computer

    diagnostic function

    The flowmeter has the function of self-diagnosis, which can diagnose and alarm the working and fault state of the instrument itself



    Certification

    1672734869133204.png


    Metering certification

    Metering type approval certificate CPA certification

    Ex Class

    ExdIIBT6 Ga/Gb

    IP Class

    IP66


  • Model Specification

    Accuracy Class

    Nominal Bore

    Nominal P

    ID of pipelines

    Qmax

    Qmin

    [mm]

    [m3/h]

    [m3/h]

    CL-1-4S

    0.5 class

    DN50

    PN16 Class300 Class600 Class900

    50

    180

    6

    DN80

    PN16 Class300 Class600 Class900

    78

    500

    17

    DN100

    PN16 PN40 PN63  Class300

    100

    850

    22

    Class600 Class900

    97.2

    800

    20

    DN150

    PN16 PN40 PN63  Class300

    150

    1900

    38

    Class600 Class900

    146.3

    1800

    36

    DN200

    PN16 PN40 PN63  Class300

    200

    3400

    56

    Class600 Class900

    193.7

    3200

    54

    DN250

    PN16 PN40 PN63  Class300

    250

    5200

    70

    Class600 Class900

    243

    5000

    66

    DN300

    PN16 PN40 PN63  Class300

    300

    7500

    94

    Class600 Class900

    289

    7200

    90

    DN350

    PN16 Class150 /PN40 PN63 Class300

    350/325

    10000/8900

    100/89

    Class600 Class900

    317.5

    8500

    95

    DN400

    PN16 PN40 PN63  Class300

    380

    12000

    120

    Class600 Class900

    363.5

    11000

    110

    CL-1-8

    0.5 class

    DN100

    PN16、Class150、Class300

    100

    1000

    12

    Class600 Class900

    97.2

    900

    11

    DN150

    PN16、Class150、Class300

    150

    2020

    21

    Class600 Class900

    146.3

    1820

    19

    DN200

    PN16、Class150、Class300

    200

    3490

    35

    Class600 Class900

    193.7

    3190

    32

    DN250

    PN16、Class150、Class300

    250

    5500

    55

    Class600 Class900

    246

    4900

    49

    DN300

    PN16、Class150、Class300

    300

    7900

    79

    Class600 Class900

    289

    7100

    71

    DN350

    PN16、Class150、Class300

    325

    9700

    97

    Class600 Class900

    317.5

    8600

    86

    DN400

    PN16、Class150、Class300

    380

    12800

    128

    Class600 Class900

    363.5

    11300

    113


    Note :  DN500 and above, Class 900 and above are customized specifications, please consult the manufacturer for specific size.


  • 圆点2.png

    CL-1-4S  installation structure and dimensions reference table


    Nominal Bore

    Nominal P

    Dimensions [mm]

    Weight [kg]

    L

    W

    H

    DN50

    PN16

    400

    210

    560

    67

    Class150

    550

    66

    PN63

    205

    550

    73

    Class300

    540

    71

    Class600

    540

    72

    Class900

    215

    565

    84

    DN80

    PN40(PN16)

    400

    235

    565

    72

    Class150

    560

    70

    PN63

    230

    565

    78

    Class300

    80

    Class600

    Class900

    240

    580

    90

    DN100

    PN16

    400

    295

    590

    81

    PN40

    600

    83

    Class150

    595

    PN63

    285

    605

    90

    Class300

    605

    92

    Class600

    615

    102

    Class900

    290

    625

    111

    DN150

    PN16

    450

    345

    660

    106

    PN40

    665

    112

    Class150

    655

    108

    PN63

    690

    135

    Class300

    680

    131

    Class600

    355

    695

    157

    Class900

    380

    710

    178

    DN200

    PN16

    600

    415

    720

    232

    PN40

    745

    250

    PN63

    450

    785

    302

    Class300

    760

    292

    Class600

    470

    780

    335

    Class900

    815

    388

    DN250

    PN16

    750

    485

    800

    306

    PN40

    820

    338

    PN63

    500

    810

    384

    Class300

    800

    372

    Class600

    510

    826

    466

    Class900

    545

    845

    526

    DN300

    PN16

    750

    535

    840

    367

    PN40

    870

    412

    PN63

    575

    870

    490

    Class300

    485

    Class600

    560

    880

    560

    Class900

    610

    900

    665

    DN350

    PN16

    800

    565

    905

    420

    PN40

    580

    920

    540

    PN63

    600

    925

    632

    Class300

    585

    925

    617

    Class600

    605

    940

    704

    Class900

    640

    1000

    806

    DN400

    PN16

    800

    640

    970

    440

    PN40

    660

    980

    555

    PN63

    670

    990

    710

    Class300

    650

    1050

    652

    Class600

    685

    1000

    872

    Class900

    705

    958


    Note : 1.DN500 and above are customized specifications, please consult the manufacturer for specific size.

                2. Flange meets GB series, HG series, ASME/ANSI series, EN series and GOST series and other relevant flange standards.



    2.png

    圆点2.png

    CL-1-8 installation structure and dimensions reference table


    Nominal Bore

    Nominal P

    Dimensions [mm]

    Weight(kg)

    L

    W

    H

    DN100

    PN16

    500

    220

    495

    90

    PN40

    235

    500

    100

    PN63

    250

    510

    105

    Class150

    230

    500

    100

    Class300

    255

    510

    110

    Class600

    275

    530

    120

    Class900

    290

    550

    145

    DN150

    PN16

    600

    285

    580

    120

    PN40

    300

    590

    140

    PN63

    345

    600

    160

    Class150

    280

    580

    120

    Class300

    320

    590

    155

    Class600

    355

    615

    190

    Class900

    380

    630

    215

    DN200

    PN16

    600

    340

    610

    180

    PN40

    375

    630

    200

    PN63

    415

    640

    225

    Class150

    345

    600

    190

    Class300

    380

    625

    215

    Class600

    420

    655

    245

    Class900

    470

    685

    285

    DN250

    PN16

    750

    405

    620

    315

    PN40

    450

    650

    335

    PN63

    470

    665

    360

    Class150

    405

    635

    320

    Class300

    445

    650

    350

    Class600

    510

    680

    390

    Class900

    545

    700

    445

    DN300

    PN16

    750

    460

    700

    380

    PN40

    515

    740

    440

    PN63

    530

    750

    490

    Class150

    485

    730

    430

    Class300

    520

    750

    485

    Class600

    560

    780

    515

    Class900

    610

    830

    590

    DN350

    PN16

    800

    520

    790

    565

    PN40

    580

    835

    595

    PN63

    600

    855

    635

    Class150

    535

    800

    585

    Class300

    585

    840

    625

    Class600

    605

    860

    675

    Class900

    640

    895

    755

    DN400

    PN16

    800

    580

    820

    705

    PN40

    660

    880

    740

    PN63

    670

    890

    775

    Class150

    595

    820

    725

    Class300

    650

    870

    765

    Class600

    685

    900

    825

    Class900

    705

    920

    860


    Note : 1.DN500 and above are customized specifications, please consult the manufacturer for specific size.

               2. Flange meets GB series, HG series, ASME/ANSI series, EN series and GOST series and other relevant flange standards.



    1671098692885907.png


    1669364823915078.png

    CL-1-8 installation structure and dimensions reference diagram



    The following drawings show the recommended length of straight pipe section when installing the typical CL-1 product of CL series ultrasonic gas flowmeter. The installation shall comply with the relevant technical requirements of GB/T 18604.


    image.png

  • CL-1 series product measuring bores covering from DN50 ~ DN700, measuring accuracy reaches 0.5 above, it is suitable for accurate and reliable custody transfer of natural gas long distance pipeline, also it is suitable for all kinds of medium and low pressure situations under the condition of natural gas, city gas, large industrial users with high precision flow metering and monitoring.

    At present, there are CL-1-4S and CL-1-8 two products in this series.

    CL-1-4S is a four-paths product, which is the first domestic product applied to the custody measurement of high-pressure natural gas. The product technology is at the international advanced level, and has been widely used in the PipeChina, and other natural gas pipeline projects.

    CL-1-8 is the latest eight-paths product, and its technical performance is in the international leading level, which can provide users with higher accuracy guarantee and reliability redundancy. lt has a larger scale ratio of 80:1 to 100:1 with more sound paths, so that in the condition of one individual sound path failed, it could continue to use other normal sound paths for effective measurement and does not affect the normal use of users; The 8 sound paths in the paralleled reflection pair layout can effectively solve the influence of the flow field distortion in the pipeline, such as turbulence flow, swirling flow, pulsating flow and other uncertain flow fields on the gas ultrasonic measurement accuracy, besides it has lower requirements on the length of front and rear straight pipe sections with convenient installation and application in compact sites.


XML 地图